Sensor module for saving energy: version with light sensor
PS 42 LS serves for switching off modules depending on the ambient brightness. It comes with two independent outputs, two digital inputs and a light sensor. The desired function of the outputs is configurable.
In combination with RB 42/RD 42 further functions are available:
- rteduction of the luminosity of RB 42/RD 42
- acoustic acknowledgement (RB 42)
Fixing | |
Welding studs | M3 × 16 |
Faceplate thickness (glass/acryl glass) | max. 8 mm |
Thickness support | 2 mm |
Connectivity | |
MicroMatch 8 poles | AWG 28 |
Screw terminal 2 × 4 poles | 0,1 - 1 mm² |
Electrical data | |
Power supply (smoothed) | 12 - 30 V DC |
Stand-by current | 10 mA |
Operating current | 35 mA (1 relay on) / 65 mA (2 relay on) |
Alternating contact (SPDT) | |
Alternating contact (quantity) | 2 (1 potential-free alternating contact) |
U (DC) | 60 V |
U (AC) | 50 V |
I (ohmic load) | max. 1 A |
P | max. 37 VA AC / 30 W DC |
Other | |
Temperature range | -20 - +65 °C |
Configuration | On site by DIP switch or via PC program “RB Configurator” and Config Kit. |