Fixation | |
Goujons soudés | M3 × 12 |
Épaisseur du plastron | 2 mm / 3 mm |
Connexion | |
Borne à vis 2 + 4 pôles | 0,1 - 1 mm² |
Contact pour connexion autodénudante 2 + 4 pôles | AWG 26 - 28 |
Éclairage | |
Éclairage individuel des champs avec cloison | X |
Registre lumineux pictogrammes | |
DEL (blanc) | X |
U | 3 - 30 V DC |
I | 2,5 mA |
Registre lumineux surcharge | |
DEL (rouge) | X |
U | 12 - 30 V |
I | 20 mA |
Buzzer | |
Buzzer | X |
U | 12 - 30 V DC |
I | 10 mA |
Fenêtre | |
Épaisseur de la fenêtre | 2 mm / 3 mm |
Fenêtre (transparente) | F 9999 |
Conformité | |
EN 81-70 | X |
EN 81-71 Class 1 | F 9999 CVG |
EN 81-71 Class 2 | F 9999 CVG |
EN 81-72 | F 9999 wg |
MA 9999 TRIPLE – Multi-indicator with emergency call pictograms and overload indicator, square; faceplate mounting. Pane plastic crystal-clear, 99 x 99 mm. Field(s) without illumination or with LED illumination, 12 V … 30 V. Separate field illumination (with partitions). Fields with pictograms according to EN 81-70:2003 with LED illumination yellow, 3 V … 30 V, for symbol “emergency call released” and with LED illumination green, 3 V ... 30 V, for symbol “emergency call accepted”. Field overload indicator with LED illumination red, 30 V or 12 V and buzzer 12 V … 30 V. Marking by film positive e. g. with customer’s logo, capacity data, lift data; film negative for overload indicator and pictograms. Connection technology at choice plug or screw terminals.