The hands-free speakerphone fire-com serves to participate in an interactive 2-way communication.
According to EN 81-72 the water- and penetrationprotected fire-com is placed behind the faceplate of the fire-fighters ficture at the fire-fighters access level.
Besides an ESD housing the fire-com is equipped with a microphone and a loudspeaker with volume control.
| Fixing | |
| Welding studs | M3 × 8 |
| Connectivity | |
| Screw terminal | 0.1 - 1 mm² |
| Electrical data | |
| Current consumption (closed-circuit status) | approx. 7 - 10 mA |
| Current consumption (operating status) | approx. 45 - 50 mA |
| Current consumption (communication) | approx. 80 - 90 mA |
| Other | |
| Temperature range | 0 - +65 °C (2 h) |
| Compliance | |
| EN 81-72 | X |